Re: [PATCH 0/6] Avoid PLT in i386 syscalls


"H.J. Lu" <hjl.tools@gmail.com> writes:

> On Wed, Oct 21, 2015 at 9:00 AM, Andreas Schwab <schwab@suse.de> wrote:
>> One of these patches probably broke powerpc.
>>
>
> Which one?

4/6.  You must use INTERNAL_SYSCALL_ERRNO to extract the errno
value from an INTERNAL_SYSCALL.

Andreas.

-- 
Andreas Schwab, SUSE Labs, schwab@suse.de
GPG Key fingerprint = 0196 BAD8 1CE9 1970 F4BE  1748 E4D4 88E3 0EEA B9D7