From: Peter Rajnoha Date: Wed, 18 Jun 2014 11:48:27 +0000 (+0200) Subject: man: add man page entry for dmsetup info -c -S/--select + minor cleanups X-Git-Tag: v2_02_107~30 X-Git-Url: https://sourceware.org/git/?a=commitdiff_plain;h=fc6e2a703b604ea5c69f7ea2e00a871c70514b73;p=lvm2.git man: add man page entry for dmsetup info -c -S/--select + minor cleanups --- diff --git a/man/dmsetup.8.in b/man/dmsetup.8.in index 10c63ab59..b545dcf28 100644 --- a/man/dmsetup.8.in +++ b/man/dmsetup.8.in @@ -40,6 +40,8 @@ dmsetup \(em low level logical volume management .IR fields ] .RB [ \-O | \-\-sort .IR sort_fields ] +.RB [ \-S | \-\-select +.IR Selection ] .RI [ device_name ] .RE .br @@ -244,6 +246,16 @@ The value \fInone\fP is equivalent to specifying zero. .BR \-r | \-\-readonly Set the table being loaded read-only. .TP +.BR \-S | \-\-select \ \fISelection +Display only rows that match Selection criteria. All rows are displayed +with the additional "selected" column (-o selected) showing 1 if the row +matches the Selection and 0 otherwise. The Selection criteria are defined +by specifying column names and their valid values while making use of +supported comparison operators. As a quick help and to see full list of +column names that can be used in Selection and the set of supported +selection operators, check the output of \fBdmsetup info -c -S help\fP +command. +.TP .IR \fB\-\-table \ < table > Specify a one-line table directly on the command line. .TP diff --git a/man/lvs.8.in b/man/lvs.8.in index 371aaf668..1afd63d42 100644 --- a/man/lvs.8.in +++ b/man/lvs.8.in @@ -198,14 +198,14 @@ selection. Precede any column with '\fI\-\fP' for a reverse sort on that column. Output columns as rows. .TP .BR \-S ", " \-\-select " " \fISelection -Display only rows that match selection criteria. All rows are displayed with +Display only rows that match Selection criteria. All rows are displayed with the additional "selected" column (\fB-o selected\fP) showing 1 if the row -matches the Selection and 0 otherwise. The selection criteria are defined +matches the Selection and 0 otherwise. The Selection criteria are defined by specifying column names and their valid values (that can include reserved values) while making use of supported comparison operators. See \fBlvm\fP(8) and \fB\-S\fP, \fB\-\-select\fP description for more detailed information -about constructing the selection criteria. As a quick help and to see full -list of columns names that can be used in selection including the list of +about constructing the Selection criteria. As a quick help and to see full +list of column names that can be used in Selection including the list of reserved values and the set of supported selection operators, check the output of \fBlvs -S help\fP command. .TP diff --git a/man/pvs.8.in b/man/pvs.8.in index ea32d787a..ccd84a5bd 100644 --- a/man/pvs.8.in +++ b/man/pvs.8.in @@ -82,14 +82,14 @@ Physical Volume, showing the start (pvseg_start) and length (pvseg_size) in units of physical extents. .TP .BR \-S ", " \-\-select " " \fISelection -Display only rows that match selection criteria. All rows are displayed with +Display only rows that match Selection criteria. All rows are displayed with the additional "selected" column (\fB-o selected\fP) showing 1 if the row -matches the Selection and 0 otherwise. The selection criteria are defined +matches the Selection and 0 otherwise. The Selection criteria are defined by specifying column names and their valid values (that can include reserved values) while making use of supported comparison operators. See \fBlvm\fP(8) and \fB\-S\fP, \fB\-\-select\fP description for more detailed information -about constructing the selection criteria. As a quick help and to see full -list of columns names that can be used in selection including the list of +about constructing the Selection criteria. As a quick help and to see full +list of column names that can be used in Selection including the list of reserved values and the set of supported selection operators, check the output of \fBpvs -S help\fP command. .TP diff --git a/man/vgs.8.in b/man/vgs.8.in index 2f71d2633..2d4946f5c 100644 --- a/man/vgs.8.in +++ b/man/vgs.8.in @@ -99,14 +99,14 @@ column. Output columns as rows. .TP .BR \-S ", " \-\-select " " \fISelection -Display only rows that match selection criteria. All rows are displayed with +Display only rows that match Selection criteria. All rows are displayed with the additional "selected" column (\fB-o selected\fP) showing 1 if the row -matches the Selection and 0 otherwise. The selection criteria are defined +matches the Selection and 0 otherwise. The Selection criteria are defined by specifying column names and their valid values (that can include reserved values) while making use of supported comparison operators. See \fBlvm\fP(8) and \fB\-S\fP, \fB\-\-select\fP description for more detailed information -about constructing the selection criteria. As a quick help and to see full -list of columns names that can be used in selection including the list of +about constructing the Selection criteria. As a quick help and to see full +list of column names that can be used in Selection including the list of reserved values and the set of supported selection operators, check the output of \fBvgs -S help\fP command. .TP