Re: __NETDEVTAB__ length is zero


On Fri, 2001-11-09 at 00:46, Chandra Sekhar G wrote:
> Hi,
> 
>     We are using cs9800 controller on a custom designed board.  I am
> able to run the TCP/IP loop back tests on this board.  In the present
> configuration of eCos, when I see the object dump of a test program (not
> a loop back program), the two global variables __NETDEVTAB__ and
> __NETDEVTAB_END__ are having a same address.  This means, there are no
> entries in the network device table.  I think, I am missing something
> during the configuration of eCos.  Can anybody give me a clue?  I did
> not configured any of the other devices.  I am using latest sources of
> eCos.

You'll need to provide a network driver structure for your controller.
Look at the driver provided for the Cirrus Logic EDB7xxx family of 
processors for an example.
  .../devs/eth/arm/edb7xxx/



Index Nav: [Date Index] [Subject Index] [Author Index] [Thread Index]
Message Nav: [Date Prev] [Date Next] [Thread Prev] [Thread Next]